News


Firefighter fire extinguishing training device
Release Time : 2024-02-24 View Count : 次
Firefighter fire extinguishing tr--ning device,Material sorting PLC control tr--ning device
1. Device composition

Firefighter fire extinguishing tr--ning device,Material sorting PLC control tr--ning device
1. Device composition
Fire hydrant series voltage pressure device is m--nly configured by small imported --r pressure tanks/domestic diaphragm -type --r pressure tanks, fire hydrant water pump units, fully automatic spray pump units, pipe valve attachments and control cabinets. Set fire hydrant spray system
Fire hydrant equipment: consisting of water guns, water bands, and fire hydrant.
Two exit fire hydrant, double exit fire hydrant, DN65. Nylon water belt: 65mm, 13m in length, 0.75MPa, water gun: 16mm. At the same time, with standard fire rolls and 20M fire hoses.
The water supply network is composed of the introduction of the pipe fire pipe, fire protection riser, and related valve valve parts. The water supply network and related valve accessories use the materials required by the fire system to regulate the water specifications to meet the pressure stipulated by the fire supply system;
Water supply pipe: 100mm galvanized steel pipe; valve: stop valve, gate valve, safety valve. All valves meet the requirements of the standard standards of the fire protection system and have inspection proof;
The roof fire hydrant is used for the use of fire hydrant to check the pilot of the water system. Single -exit fire hydrant: DN65; water pump junction, fire pool, fire water tank, etc.
Water pump junction: above ground formula, execution standards:
Product Standard "Fire Fighting Pump Combination" GB 3446
Engineering Standard "Code for Fire Fire of the Architecture" GB 50016
"Code for the Construction Quality Acceptance of Water Dr--nage and Heating Projects" GB50242;
Water pump requirements: The amount of essential steam erosion: 4
Material: carbon steel/cast iron
Power: 1.1-18.5kW (W)

Firefighter fire extinguishing tr--ning device,Material sorting PLC control tr--ning device
Note: PLC, inverter can be configured separately, or you can also use the PLC inverter speed adjustment tr--ning device to use
Equipment structure:
Material sorting and control tr--ning model is a metal structure. The I/O terminal of the PLC module, the wiring terminal of the inverter, the connection terminals of each commonly used module and the connecting terminal are connected to the safe socket. The circuit of the instruction switch, the photoelectric switch, and the indicator element is connected through the terminal row. The combination of the plug -in -line connection circuit and the terminal brand connection circuit not only ensure the tr--ning, formation and consolidation of the basic skills of students, but also to ensure the rapid, safe and reliable circuit connection.
Technical Parameters
Power: single phase AC220V, 50Hz
Power: <200W
Size: not less than 800*515*220mm
Some tr--ning items:
1. Installation and debugging of the pneumatic system
(1) Installation of the dynamic direction control circuit (2) Installation of the pneumatic speed control circuit
(3) Installation of pneumatic order control loop (4) Connection of pneumatic system gas path
(5) Position adjustment of magnetic switch (6) Pneumatic system debugging
2. Installation and debugging of the inverter (need to be equipped with a variable converter)
(1) Connection of the m--n circuit of the inverter and AC motor (2) The parameter settings and operation of the inverter panel
(3) Inverter panel control AC motor speed regulation (4) Control motor start -stop through the external terminal of the inverter
欢迎咨询Firefighter fire extinguishing training device相关问题,我们是源头工厂,有标准工业厂房生产基地,欢迎前来考察,如有Firefighter fire extinguishing training device其他问题,可联系19957812178